LC filter /Semi-lumped element filter

 

BoCen’s micropackaging LC filter has developed a complete categoryincluding LC bandpass filterLC lowpass filterLC highpass filterLC band-reject filter and LC combining filter, with totally 3000-5000 types of fixed modules, covering 0.05MHz~6000MHzand up to max power of 80W, being of low insertion loss, good passband VSWR and high out-off-band attenuation, which adopt 0.1dB chebyshev for response design, or ButterworthBeseelelliptic function and linear phase shift depending on the specific requirement.

一.           General Capability:

 

frequency

(MHz)

Passband

VSWR

Relative bandwidth @3dB (%)

Square ratio

Impedance

Numbers of Sections

Average power

Operating temperature

Relative

moisture

0.05~6000

1.2~1.5

0.04~200%

≥1.4

50Ω

2-13

1W

-55~+85

0~95%

 

High-frequency vibration test 1055Hz10 minutes in each axial direction552000Hz10g

Shock test::half sine wave30g11mspeak value 300m/s2 speed variation 2.07m/s

一.        Numbers of section

       The numbers of sections is determined by the following steps:

1.Fix the central frequencye.g.  f0=500MHz

2.Fix the bandwidthe.g.  60MHz at 3dBi.e.f0=±30MHzthe relative 

bandwidth=12%

3.The required out-off-band attenuatione.g.  attenuation≥40dB at 400MHz and 600MHz

4.Fix the bandwidth of 3dB from the central frequency  =rejectband frequency central frequency/ 3dB bandwidth

                    e.g.400 -500/ 60 = -1.67

                  600 -500/ 60 = +1.67

5.Numbers of sectionsnLnumbers of sections for low end= 4

                                                       nHnumbers of sections for high end= 5

                                                       then n=maxnLnH=5

一.           Insertion loss calculation

1.Formula for the MAX insertion loss at central frequency

A0(dB) =loss constant)×(numbers of sections0.5)/%  3dB bandwidth0.3notethe real insertion loss is expected to be better than this formula

 

 

 

1.Loss constant

 

Central frequencyMHz

2

159

160

199

200

299

300

399

400

499

500

599

600

699

700

799

800

899

900

999

1000

6000

Loss constant

8.8

7.8

6.8

5.7

4.9

4.4

4.0

3.7

3.5

3.25

3.0

 

 

 

一.           PN rules

The PN of LC filters consists of performance parameters and package. The standard input/output lead is φ0.5 or φ0.8 signal probe. In case of SMA, it’s required to be marked following the package. 

Note1

1In addition to the parameters, customer also can offer PN according to our rules when placing orders

2The old PN is also effective.

 

LC bandpass filters

FB×××   ××/ ×  ×    ××  ××

  1            2  3      4       5   6

      Interpretation FB— bandpass filter

             1—central frequency f0taking MHz for unit

             2—passband BWtaking MHz for unit

             3—bandwidth feature   T—3Db BW

                                               O—1dB BW

                                               H—0.5dB BW

                                               F—0.2Db flat BW

                                            P—Dot frequency

             4— numbers of section

               5—package Pradial pin

                                       Caxial probe

                                       IparallelII probe

                                       Lright angleL probeL

                      DDiP dual-in-line integrate circuit pin

                                       SSMT

               6—package SN

 

LC lowpass filter

FL×××/×××××× ××

 1   2     3        4    5

  InterpretationFL—lowpass filter

                1—Cutoff frequency, MHz for unit

                2—Cutoff frequency features 

                                   T—3dB BW 

                                   O—1dB BW

                3—frequency at the suppression point

taking MHz for unit               

4/5—package series

 

LC highpass filter

FH×××/× ××××× ××

   1    2    3       4    5    

InterpretationFH—highpass filter

              1—cutoff frequency fCtaking MHz for unit

              2—cutoff frequency features 

                                  T—3dB BW

                                  O—1dB BW

              3—frequency at the suppression point

taking MHz for unit 

4/5—package series

 

 

LC Notch Filter

FR×××-×××/×× -×× ××

   1      2      3     4    5    

 InterpretationFR—band-reject filter

           1—central frequency, taking MHz for unit

           2—bandwidth of reject band, taking MHz for unit

           3—suppression of reject band, taking dBc for uni

           45—package series 

 

LC Duplexer

FDS-×/× -× ×××× ××

         1  2  3   4         5    

 InterpretationFDS—combining filter

1—CH1 central frequency, taking MHz for unit

2—CH2 central frequency, taking MHz for unit

                     3— frequency feature:  B for bandpass filter

                              P for dot frequency filter

                     4— bandwidth of pass band (only for bandpass filter

5— package series

 

蜀ICP备08111153号-1